seperate task AO and CO

HiCan anyone help me to diagnosis the problem. I have a program to generate a counter output which is triggered by an AO of 2 channels. the output of the countered is fed to the RTSI route. This...

View Article


How to run the two events at the same time by using event structure

In my project, I have to run two stepper motor which can run both forward and reverse direction by changing the control in front panel so I am using event structure. In front panel I gave two separate...

View Article


can I programatically format array of strings?

I am using a 2D array of strings to display a memory map. One of the things I was interested in doing was highlighting individual cells that might be changing values (in this case, in general the...

View Article

SourceGear Vault Pro & LV 2011/2012

Saw some posts from back in 2009 that using SourceGear Vault Pro with LV's built in source control, does not work.Is anyone using SourceGear Vault Pro to manage LV projects / sources externally?Is...

View Article

Control of ethernet packet sniffer in LV

I got a new Ethernet packet sniffer from Kunbus company and I need to control it on Labview. The manufacturer doesn't have any dll library that allows me some "easy" automation (like I did before with...

View Article


Fulltime Labview Programmer position available

Small, innovative company looking for a full-time LabVIEW programmer.  The ideal candidate should already be a CLD, however, we will consider CLD equivalent experience and CLAD.  Your commitment will...

View Article

How do I fix my VI when error -1074000000 and -213 "Init ignored" comes up...

When I run Test Main 002.vi in debugging mode, this error continues to pop up.  I am finding and recording the voltages for a Keithley 2700 multimeter.  I have Test Main 002.vi call on Read Volt.vi and...

View Article

Real time data monitoring using multiple thermocouples via indicators and...

I apologize in advanced for this question is probably somewhat simple but I am brand new to labview as well as to the forum and could use some pointers. I have a CompaqDAQ with two 9213 16 channel...

View Article


XNET session problem on cRIO

I’m having a problem reading all the CAN signal into my LV vi through an XNET session on a NI 9862 cRIO module.  I’ve got roughly 12 signals available to read from my device, but I can only get values...

View Article


Driver visa session looping issue

Hi, This is the first time I've ever setup a loop with a visa driver session in it. I am attempting to collect an array of flux data. The array indexes correspond to physical (x,y)  locations on the...

View Article

pyrometer acquisition date

Dear I am Nicola PhD student , I bought a pyrometer Micro-Epsilon thermoMeter, the instrument give a output 0-5 V, it is able to measure the temperature between 100 -1000 C, I connect with the desktop...

View Article

Typing Multi Line Text During Run Time with Horizontal and Vertical Limits

Hi All, My goal is to be able to type a multi line text in a string control during run-time that will have certain horizontal limit (indicating how many characters are allowed) as well as certain...

View Article

synchronized analog and digital data

Hello all, I would very much like some help with what I am trying to accomplish, if you don't mind. I am trying to synchronize the acquisition of both analog and digital using a common trigger that...

View Article


Producer/consumer inside producer/consumer

Hello all,  I am using a producer/consumer event structure within a producer/consumer....not sure if this is the best approach.  The main vi is setup to perform several different tests based on the...

View Article

Calling COM components running as a Windows 7 service (NOT A WEB SERVICE!!!)...

First, what I'm trying to do is completely new terrority for me and I've been looking everywhere unable to find found a solution. I've reviewed the following resources and have tried them out but to no...

View Article


averaging 5 minutes of data--not running average

I need to average 5 minutes worth of data, save that average, and then start over on the next 5 minutes of data, averaging that block of data.  I tried using the pt-by-pt mean function in LabVIEW, but...

View Article

How to Subtract two images created from Oval ROIs?

I am trying to subtract two images that have each been created from a user-selected oval shaped ROI. I can preform the image subtraction using the original images, and then selecting an ROI (I can only...

View Article


Synchronization of output and input signal

Hi all, I have 11 voltage steps and and each step needs to come on after 5 seconds. I want to generate a new txt file of the output data of a sensor everytime the voltage changes. For the generation of...

View Article

Remote startup and shutdown of of PXIe controller running Labview RT (WoL)

I would like to be able to remotely start up and shut down a PXIe-8133/PXIe-8130 controller remotely over the LAN.   I can see that the hardware specs for the PXIe-8133 supports wake on lan (WoL), but...

View Article

NI device simulated vs. real in EXE

I have a problem here where I have 2 computers, I'll call them A and B, where A is a laptop that has the full LabVIEW software installed on it, but B is the desktop actually used in the lab to connect...

View Article