Analizing Cluster Array with elapsed time

Hi,In my VI, i have to 10 valves and each valve has a "open status", "closed status", a "command to open" and a "command to close". Normaly my valve takes 3 seconds to be open after a request, so if...

View Article


Hamamatsu DCAM_API init function reconstruction in vb

Hello,I am working on controlling highest resolution x ray sensor from Hamamatsu C9732DK. 12cmx12cmThey have example for Labview, so it is very easy to rewrite in visual basicOnly problem that first...

View Article


sampling rate

Hi everybody,               I need some ideas to work with sampling rate, here i have some doubts.1. I was acquiring a voltage signal from daq device usb 6211 with rse configuration mode and i have...

View Article

LabVIEW PID controlled PWM output

Dear All, I need to control the heater with set temperature. My idea is to use PID control which can output duty cycle percentage and in-turn generate the PWM signal to control the SSR using single...

View Article

Image may be NSFW.
Clik here to view.

Visa Serial interface problem

I am trying to read an array of string using the code as attached. I have an error with "scan from string" block every time I run the program. you can find sample of my data to be sent by my hardware...

View Article


Find if string contains valid float

I have attached a VI.A separate MCU board, sends data on computer COM port, in ascii format as below: $-999.999;-999.999? Total length of string is 19 max. It can be less than 19 also, for example...

View Article

Labview 2017 Co-simulation Multisim VI

I am trying to build a hybrid power system with wind and solar power in Labview 2017. I have completed the Wind Turbine part of the system but I have some troubles with the PV. I built a circuit in...

View Article

Unable to analyse ECG signal

Hai, I'm new to LabVIEW and currently doing a project about bio-signals. I came up with a program and I was able to collect my bio-signals. However, I'm unable to analyse it. My ECG analyse program...

View Article


Image may be NSFW.
Clik here to view.

Question about Format Into String Function

Hi, I make file name using Format Into String Function. I want to make file nameDate_Name_bio.txtbut Format Into String Function create blank(spacing?)So, file name is made Date _ Name _ bio .txtHow...

View Article


Export projects with Scilab Nodes

Hello everyone! I am currently trying to export a LabVIEW-project with Scilab nodes into an application file (.exe). I noticed that all VIs which include Scilab-nodes cannot be exported to an...

View Article

field fox microwave analyzer version N9918A and LabView

Hi,I have Labview 2015 , but no experience with it,I have a project implemented on labview,it consist of wide band spectrum sense code.-the first question is :-if I make a spectrum scan   for a signal...

View Article

Control about LabView activex a CANoe test environement

I have a problem, I want control about LabView a CANoe test envirionment.But If I add an automation refnum, I can only choose between 2 classes CANoe.IApplication3 and CANoe.IMeasurement, I saw a...

View Article

write to spreadsheet file issue and in sampling rate

Hi to all,      I have created some vi to acquire a signal and save it in a csv file but when i was analysing it, at the 0th sec , the values which it was acquired is displayed in a same array that...

View Article


New VI - default window size

Is there a way to specify the default window size when the "new VI" action is invoked? Both for the block diagram and front panel? In 99% of cases the front panel is way too large by default. I know I...

View Article

New class VI - template modification

Is there a VI file that can be edited to change the default generated class VI for both static and dynamic dispatch?

View Article


Image may be NSFW.
Clik here to view.

LabView communcation with rs485

I have a labview 2012. Now i try communicate with schneider electric em1200 through rs485 protocol. I do the program. But it show what we give to write buffer. please any one help me. how to program. 

View Article

Synchronization of two DAQ Assistant USB-6003

Hi all, I'm creating a VI which is supposed to use two boards USB-6003 to take some measurements. The first one is reading a voltage from two lasers which measure distance, the second one reads a...

View Article


Arduino UNO+HC-SR04

Hello,I tried all solved and unsolved examples of Ultrasonic HC-SR04 sensor using Arduino of this discussion forum. But No-one works well. All VIs showed "Timeout Error" except this attached VI. But...

View Article

Read VISA signal on function generator

Hi all, I´m using labview (VISA I/O) to remote control a TGP3122 function generator. I set the wave parameter (kind of wave, frequency, amplitude ecc), turn on the wave, and then I want to read the...

View Article

Image may be NSFW.
Clik here to view.

A Problem of "Reference"

Hi, I have a problem to refer to a type which is contained into a cluster which is contained into an array. So the array is an array of clusters. Here is my SubVIAnd the references which are contained...