SIN generation PtByPt doesn't work
Hello, In the fragment that follows there are 2 signal generation blocks from PtByPt palette:noiseSINNoise works perfectly, whereas SIN doesn't. Where is a problem ? Thanks
View ArticleMouse Scroll does not work in case structure case drop down on Windows 10
On Windows 10 machines there seems to be an issue where in LabVIEW the mouse scroll works fine for scrolling you front panel and block diagram but it does not work for any drop-down list, i.e. rings,...
View ArticleMeasuring of DUTY CYCLE with myDAQ?
Hello everyone, sorry for my beginer question. Is it possible to measure duty cycle with myDAQ? If yes, could you give me an advice please how? I want to measure temperature with temperature sensor...
View ArticleHow do I turn the analog output off using DAQ Assistant? Iam using a NI 6009...
Iam trying to use the analog output to trigger a external relay and would like the ability to turn the output off when stopping the labview program.
View ArticleWrite Continuous Analog Strain Inputs to Spreadsheet with Headers
I am using a cDAQ-9178 chassis with an NI 9235 strain gauge model to collect analog strain inputs from 3 gauges. I currently have a program (attached as Finite_Strain.vi) that collects this data and...
View ArticleVisual Stuido LVUserEvent
Hi, I'm trying to build the application "LVUserEvent" (http://www.ni.com/example/26480/en/) in Visual Stuido 2015, but I can not, I always get an error to build. I'm no expert in Visual Studio and do...
View ArticleThe number of channels in the data does not match the number of channels in...
Hello The attached VI modifies an input signal (train pulse). The signal is delayed (t1, t2, ti) and it will stay like that for an amount of time (T1,T2,....Ti). After processing such signal, the...
View ArticleHi., I'm using TDC001 controller with CR1/M-Z7 motor
Hi., i need the motor to run from one position to another and reverse back. What will i do? or which option i wil choose like move absolute rot ...
View Articlelabview supportable stepper controller
Hello every one.... iam searching a lot for labview program supportable stepper motor controller...i have attached a texas instrument product it is a stepper controller....if anyone used...
View Articlecombining TDMS files
Hello,I use LabVIEW 8.5 to collect EEG data that are saved into TDMS files. Sometimes things go wrong, like an electrode falling off the participant, and we need to stop therecording and then restart...
View ArticleQAM with NI-USRP-2950R
Dear All I want to make a QAM modulation in labview using NI-USRP2950R but I couldent connect the two RFs together to send the same transmitter waveform in the same time. If you have examples could you...
View ArticleFPGA Code Generation Error
When I build my FPGA I get the following error: An internal software error has occurred. Please contact National Instruments technical support at ni.com/support with the following information:Error...
View ArticleSignal Processing/Signal Generation palette - couple of questions
Hello Working with Signal Processing / Signal generation paletteI have met some difficulties.Here are some of them:some blocks works properly, whereas others not at all, e.g. on the snippet that...
View ArticleHow to save array from text file input
Hello, I'm very new to LabVIEW, so apologies if I use the wrong terminology. I have made a VI that reads 25 text files into a 3D array. When I click run I need to select the 25 text files. Is there a...
View ArticleExe not communicating in other PC
Hello I have created a VI which is communicating over opc to siemens plc,and is working fine.now when i created an exe application and used it in another pc which has labview,it doesnt...
View Article3D coordinates of point on surface
I have a data series describing the characterisation of an induction motor, wherein there are 2 independent variables, Input Current and Rotor Speed, and one dependent variable, Output Torque. During...
View ArticleTDMS File starts recording data at 20Hz, but after a short time drops to
How can i find where this is happening? basically if I open my tdms file after about an hour, the first few thousand samples are 20/sec, but then it slowly drops down to 19/sec 16/sec, etc. I am...
View ArticleVisa/IVI resource stops working after 100 times
I have a Labview 8.6.1 application that has been running for a long time now. I replaced the workstation, after a period of time the Pickering PCI switch stops working. I created a utility to find...
View Article