Combining data and table display
I have two questions that are probably really simple, but I've been working at this a few hours and still haven't found the solution.Need to put a time stamp into the table that has all the data from...
View Articleusb 6351 DIO between Two Ports
Hi All,I am using Usb 6351 DAQ card and having a small problem to simultaneously sending and receiving Digital Data. What I am trying to do is send digital signal out from port0:line0 and receive the...
View Articlepass on arrays from cRio
Hello, can I pass on arrays as network/shared variables?I get errors 1950678941 and 1950678965Read variable with timeout and cannot be converted to data type of this shared variable node.Should I...
View ArticleLabVIEW and communication via Profinet
Hi, I have a cRIO PN slave device, and I'm trying to send boolean and real data throught profinet to Siemens s7.I have configured cRIO PN as on the screen below(comsoft) and on TIA Portal installed...
View ArticleSampling at two different sampling rates using NI cDAQ 9188 and NI 9215
Good day, LabView users!I am trying to set up a LabView VI to collect data on multiple channels, across multiple cards/modules, at different sampling rates. Here's a brief summary of my application:In...
View ArticleNeed help with manage user operation on multiple instant of LabVIEW...
I am in responsible for maintaining applications created by my ex coworker. Let says he created 3 LabVIEW applications A, B, C. When A is launched it will also launch B and C (use command line-vi to...
View ArticleUnexpected Data
I have two controllers cRIO 9068 (OS is NI Linux Real-Time) and cRIO 9081 (OS is Phar Lap ETS). They both have the same analog input card NI-9229. They are both viewing the same analog input (Neutral...
View ArticleXY Graph Multi Plot - Data does not Match Graph
I am trying show two plots on an XY Graph and the data I feed into the graph does not match what the graph shows me. When I right click the graph and export the data to excel the numbers are correct...
View ArticleSVN for use with LabVIEW
Hi all, We are in the preliminary stages of implementing a software source control here where I am working, to the best of my knowledge Apache SVN. Can y'all direct me to some sites showing...
View ArticleWindows, RT, and packed libraries
I'm trying to generate a common codebase for use across many test systems. These systems run both Windows and NI Linux RT. There are many code modules and low level libraries that do literally the same...
View ArticleAVI refnum with Get File Size
Using LV2014 w/Vision 2014. While saving frames to an .avi file, I want to check the file size prior to each frame write to make sure to not go over the limit. LV won't let me wire an AVI Refnum to...
View ArticleRamp generating using NI 6211
I am very new to Labview and I need some help here. Part of my aim is to generate a ramp signal for my scanner.I searched the forum and found an answer which is not a bad fit for my aim (attached...
View ArticleOnly sending cluster to client once TCP/IP
Hi, so I am writing a programme that should the data that is being used on one application to another application. But it is only sending the first state and not updating or sending anything else once...
View ArticleMy device (niScope-5102) is detected in MAX, but not in Labview
Hi, My niScope-5102 was working fine even though it is quite old. Today, I formatted my PC and reinstall windows 10 (It was windows XP) and Labview 2017. Suddenly, my 5102 is not detected in Labview....
View ArticleTrouble with building executable. reporting"resource not found" error
Hi Folks: I am trying hard to build an exe from a LabView VI as attached. However, it keeps reporting "resource not found" error. It seems that it is having trouble calling the .dll or subVI files....
View ArticleExe gets deleted
hi there!i am trying to build an application on labview. when i build by application it generates a .exe in builds folder but when i run that exe it shows an error that the file doesn't exists and...
View ArticlecRIO modules gone after reboot, variables in limbo
hello, after reboot the cRio 9074 all my modules disappeared. Should be the 9870, 9871 and PB module.I added some variables on the RT target, then built tha startup.exe and the PC main vi.The PB module...
View Articleflat sequence problem
I had written a program, my problem is for the first iteration program is Ok, for the next iteration it goes to the last flat sequence and run its elapsed time, I want for each iteration of program,...
View ArticlecRIO 9023 not booting correctly
I have a crio 9023 that is failing after installing any software to it. Attached is the console output: cRIO-9023 Boot Copyright 2008-2009 National Instruments Corporation...
View ArticleDoes LabVIEW RT-Linux support XPATH or XQuery?
I am starting a project that will be using LabVIEW RT-Linux.I would like to know if the Linux version of Real Time supports DOM or the ability to support a XPATH or XQuery type queries? I know that in...
View Article